Vertical Laminar Air Flow

//Vertical Laminar Air Flow
Vertical Laminar Air Flow 2018-05-04T07:19:10+00:00

Project Description

Vertical Laminar Air Flow

Vertical Laminar Air Flow
Make Enquiry

We have to require comprehensive range of high performance vertical Laminar Flow clean air cabinets. Modular construction, combining aesthetic appeal with functional utility and efficiency. These are designed to meet the filtration, illumination, Noise & Vibration requirements and US Federal Standard 209 B (BS 5295) Providing air to meet class 100 (class I) conditions, to the extent applicable. It is Ideal for microbiological manipulations. work with bioassays sterility testing & research work. vial filling & bunging operation in parenteral units & for general dry-processing work in semi consuctor industry etc. Provides a comfortable ‘sit down’ working position for the operators.

CONSTRUCTION :

All laminar flow clean air cabinets are basically constructed out of thick CRC sheet – powder coated or thick teak wood board which is termite and insect proof. Work table is made of S.S.304 and side panels of thick transparent plexi glass.

AIR FLOW AND FILTRATION :

Laminar flow principle involves double filtration of air. Atmospheric air is drawn through pre filter and is made to pass through highly effective HEPA (High Efficiency Particulate Air) Filters having efficiency rating as high as 99.99% with cold DOP adn 99.97% with hot DOP, thus retaining all airborne particles of size 0.3 micron and larger. Double filtered air blows in laminar flow through the work table at designed velocity of 90 ft. min ± 20%.

BLOWER MOTOR ASSEMBLY:
Duly balanced, direct drive motor blower units sized to provide adequate air flow volume over the entire surface of HEPA filter. Fitted with standard make motor and operates with minimum noise level i.e. lower than 65 db on scale and vibration less than 2.5 um.

LIGHTING:

Work area properly illuminated by diffused, glare free fluorescent Light.

POWER REQUIREMENT:

230 V. Single Phase, 50 Hz, AC supply, It’s Body will be made of cold rolled sheet duly powder coated. Table made of S. S. 304, front door of clear acrylic, UV lamps will be Phillips make. Other standard accessories such as Manometer, gas inlet, castor wheels, illumination, Two additional power point are require.

Working Area : 4’×2’×2′.

Size of HEPA Filter : 4’×2’×6′

HEPA Filter(with unit): One

PRE Filter(with unit) : one

Illumination : 40 Watts.

Working Size:

2ft x 2ft x 2ft
3ft x 2ft x 2ft
4ft x 2ft x 2ft
6ft x 2ft x 2ft